| a.c. voltage (auto-ranging) |
90-264 V rms, 47- 63 Hz 100 VA |
| Battery Charge Time |
2.5 hours deep discharge, 2 hours normal discharge |
| Battery life |
1.1 V, 5.2Ah Li-ion batteries, meet IEC 62133:2003, MIT1525 has 2 battery packs
6 hours (typical) continuous testing at 5 kV with a 100 MΩ load |
| Test Voltage |
250 V, 500 V, 1000 V, 2500 V, 5000 V, VL |
| Lock test voltage |
100 VL to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, 5 kV to 15 kV in 25 V steps |
| Test voltage accuracy |
+4%, -0%, ±10 V nominal test voltage at 1 GΩ load (0°C to 30°C) |
| Resistance range |
10 kΩ to 15 TΩ @ 5 kV, 10 kΩ to 20 TΩ @ 10 kV, 10 kΩ to 30 TΩ @ 15 kV |
| Accuracy |
5000 V 2500 V 1000 V 500 V 250 V
±5% from 1MΩ to
1 TΩ 500 GΩ 200?
?20% from 1M? to
10 T? 5 T? 2 T? 1 T? 500 G? |
| Guard terminal performance |
Guards out parallel leakage resistance down to 250 k? with a maximum additional resistance error of 1% with a 100 M? load |
| Display analog: |
100 k? to 10 T? |
| Digital: |
10 k? to max. a above |
| Short circuit / charge current |
3 mA @ 5 kV, 10 kV, 15 kV |
| Insulation test alarm: |
100 k? to 10 G? |
| Capacitor charge |
<3 s/?F at 3 mA to 5 kV |
| Capacitor discharge |
<120 ms/?F to discharge from 5000 V to 50 V |
Capacitance range
With test voltage set above 500 V |
0 nF to 25 ?F |
| Capacitance measurement accuracy |
?10% ?5 nF |
| Current range |
0.01 nA to 6 mA |
| Current accuracy |
±5% ±0.2 nA at all voltages (23 °C) |
| Interference |
3 mA from 450 V to 5 kV |
| Voltmeter range |
30 V to 660 V a.c. or d.c., 45Hz – 65Hz |
| Voltmeter accuracy |
±3%, ±3V |
| Timer range |
Up to 99 minutes 59 seconds, 15 second minimum setting |
| Memory capacity |
5.5 hours logging @ 5 sec intervals |
| Test modes |
IR, IR(t), DAR, PI |
| Interface |
USB type B (device) |
| Real time output |
1 Hz output readings (V, I, R) |
| ENVIRONMENTAL |
| Maximum altitude |
3000 m |
| Operating temperature range |
-4 °F to +122 °F (-20 °C to +50 °C) |
| Storage temperature range |
-13 °F to +149 °F (-25 °C to +65 °C) |
| Humidity |
90% RH non-condensing at 104 °F (40 °C) |
| IP rating |
IP65 (lid closed), IP40 (lid open) |
| Safety |
CAT IV 600 V to 3000 m altitude |
| a.c. voltage (auto-ranging) |
90-264 V rms, 47- 63 Hz 100 VA |
| Battery Charge Time |
2.5 hours deep discharge, 2 hours normal discharge |
| Battery life |
1.1 V, 5.2Ah Li-ion batteries, meet IEC 62133:2003, MIT1525 has 2 battery packs
6 hours (typical) continuous testing at 5 kV with a 100 MΩ load |
| Test Voltage |
250 V, 500 V, 1000 V, 2500 V, 5000 V, VL |
| Lock test voltage |
100 VL to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, 5 kV to 15 kV in 25 V steps |
| Test voltage accuracy |
+4%, -0%, ±10 V nominal test voltage at 1 GΩ load (0°C to 30°C) |
| Resistance range |
10 kΩ to 15 TΩ @ 5 kV, 10 kΩ to 20 TΩ @ 10 kV, 10 kΩ to 30 TΩ @ 15 kV |
| Accuracy |
5000 V 2500 V 1000 V 500 V 250 V
±5% from 1MΩ to
1 TΩ 500 GΩ 200?
?20% from 1M? to
10 T? 5 T? 2 T? 1 T? 500 G? |
| Guard terminal performance |
Guards out parallel leakage resistance down to 250 k? with a maximum additional resistance error of 1% with a 100 M? load |
| Display analog: |
100 k? to 10 T? |
| Digital: |
10 k? to max. a above |
| Short circuit / charge current |
3 mA @ 5 kV, 10 kV, 15 kV |
| Insulation test alarm: |
100 k? to 10 G? |
| Capacitor charge |
<3 s/?F at 3 mA to 5 kV |
| Capacitor discharge |
<120 ms/?F to discharge from 5000 V to 50 V |
Capacitance range
With test voltage set above 500 V |
0 nF to 25 ?F |
| Capacitance measurement accuracy |
?10% ?5 nF |
| Current range |
0.01 nA to 6 mA |
| Current accuracy |
±5% ±0.2 nA at all voltages (23 °C) |
| Interference |
3 mA from 450 V to 5 kV |
| Voltmeter range |
30 V to 660 V a.c. or d.c., 45Hz – 65Hz |
| Voltmeter accuracy |
±3%, ±3V |
| Timer range |
Up to 99 minutes 59 seconds, 15 second minimum setting |
| Memory capacity |
5.5 hours logging @ 5 sec intervals |
| Test modes |
IR, IR(t), DAR, PI |
| Interface |
USB type B (device) |
| Real time output |
1 Hz output readings (V, I, R) |
| ENVIRONMENTAL |
| Maximum altitude |
3000 m |
| Operating temperature range |
-4 °F to +122 °F (-20 °C to +50 °C) |
| Storage temperature range |
-13 °F to +149 °F (-25 °C to +65 °C) |
| Humidity |
90% RH non-condensing at 104 °F (40 °C) |
| IP rating |
IP65 (lid closed), IP40 (lid open) |
| Safety |
CAT IV 600 V to 3000 m altitude |