Description

? True RMS measurement
? For measuring solar, PV systems
? Auto ranging
? Bar-graph indication
? Data hold function
Ϡ3000V DC Voltage measurement
Ϡ2000V AC Voltage measurement
ϠAC mA/uA measurement
ϠDC mA/uA measurement
? Low battery indication
? Auto power off
? Low power consumption
ϠRugged and compact
? Comply with
IEC / EN 61010-1, CAT III 1000V
IEC / EN 61010-1, CAT IV 600V
? Comply with CAT III 1000V for the
range of 0~1000V AC/DC

 

DC Voltage
  Ranges   Resolution   Accuracy
400mV 0.1mV ±(0.5%rdg+5dgt)
4V   1mV
40V  10mV
400V   100mV
1000V for CE   1V
3000 for general   1V ±(1.0%rdg+3dgt)
Input impedance : 10M
 AC Voltage
  Ranges   Resolution   Accuracy
400mV 0.1mV ±(1.0%rdg+5dgt)
4V   1mV
40V  10mV
400V   100mV
1000V for CE   1V
2000 for general   1V ±(1.5%rdg+3dgt)
Input impedance : 10M
DC mA / µA
  Ranges   Resolution   Accuracy
400µA   0.1μA ±(1.2%rdg+5dgt)
4000µA   1μA
40mA  0.01mA
400mA   0.1mA
Overload Protection 0.5A/1000V fast blow fuse for 400mA
AC mA / µA
  Ranges   Resolution   Accuracy
400µA   0.1μA ±(1.5%rdg+3dgt)
4000µA   1μA
40mA  0.01mA
400mA   0.1mA
Overload Protection 0.5A/1000V fast blow fuse for 400mA
 GENERAL
  Dimensions 221mm(L) x 110mm(W) x 57mm(D)
  Weight
(battery included)
Approx. 507g
  Power source 1.5V (AA) Alkaline battery x 2
  Safety standard IEC / EN 61010-1 CAT III 1000V
IEC / EN 61010-1 CAT IV 600V
EN 61326-1